This website requires Javascript for some parts to function propertly. Your experience may vary.

The FL3X Interface-L is the middle-class solution of the FL3X Interface Family. | STAR ELECTRONICS

FL3X Interface-L

The FL3X Interface-L is a mid-range bus interface.

Article number: 3-V0872A01

The FL3X Interface-L is the middle-class solution of the FL3X Interface Family with a 1000BASE-T Uplink Port to the Logger or Measurement PC. It can be used with the Standard CMP or PLP Logger Protocol for the usage with a datalogger or alternatively as a full functional Interface with writing and reading ability with our Driver for Linux and Windows.

Product Information

Description

With the FL3X Interface family a highly variable automotive bus interface solution for Dataloggers and PCs, which supports the current and upcoming bus and network systems via plug able physical layer modules and the usage of a FPGA.

The FL3X Interface-L has one FPGA for the hosting of bussystems and five FL3X Tiny3 Slots for pluggable transceivers which can provide FlexRay, CAN-HS/FD/SIC and LIN/SENT channels. Because of its free mountable Tinyslots and the FPGA, it can be extended with any available or upcoming FL3X Tiny3 and communication channel.

  • 1Gbit/s Ethernet and WiFi interface

  • 5 x FL3X Tiny3 exchangeable Physical Layer slots

  • 5 x M9 connector

  • 8-42 V

  • LEDs signal the state of the network

Advantages
  • Five pluggable transceiver modules (2-6 channels per module depending on the bus system)

  • Pluggable transceiver modules available for CAN-HS, CAN-FD, CAN-FD SIC, FlexRay, LIN, SENT*, K-Line*, RS232*, SPI*

  • Compact form factor

  • Synchronous timestamp generation for most of the bus interfaces(

    resolution up to 1 µs)

  • Configurable bus termination

  • Bosch E-Ray IP core FlexRay controller

  • Bosch D_CAN IP core CAN controller

  • Bosch M_CAN IP core CAN-FD Controller

  • Intel Triple-Speed-Ethernet Ethernet controller

  • V2.1 A FlexRay protocol specification

  • V2.0 A/B CAN protocol specification

  • ISO 11898-1:2015 CAN protocol specification

  • Bosch CAN-FD specification 1.0

    * API possible but not available at the moment

CAN-HS / CAN-FD*

  • Silent mode useable for listening without bus interference

  • Configurable TX-acknowledges

    *no ACK Flag, no Bus Errors

FLEXRAY*

  • Asynchronous monitoring mode allows listening without FlexRay-Synchronicity

  • Configurable TX-acknowledges

  • Chronological correlation of bus messages with one timestamp base

    *no state messages available, no bus states, no error messages, no bus symbols, no CC State

Technical Details

Technical Details

Altera Cyclone V SOC (integrated ARM Cortex A9 Dual Core CPU)

1 GByte DDR3 RAM

5 bus connectors that can be allocated flexibly via pluggable transceivers

2-6 bus interfaces are available on each bus connector

Up to 4 FlexRay controllers (4 Bosch E-Ray Cores)

Up to 8 FlexRay channels (4 channel A and 4 channel B) available on the bus connectors

Up to 15 CAN-HS bus interfaces

Up to 10 CAN-FD bus interfaces

1 Gbit/s Ethernet configuration interface

Integrated WiFi module (b/n/g)

Downloads

Downloads
Specsheet specsheet_fl3x-interface-l.pdf 1.76 MB Download
Driver Windows / Linux fl3x_driverpackage_2024-06-18.zip 501.12 MB Download

Trainings

FL3X Training SOME/IP & Ethernet

Make your communications future-proof! In our new training course SOME/IP & Ethernet we will provide you with all the technical knowledge you need. Whether in German or English, you can choose in which language the training takes place. You will receive the documents in English. You can also decide where your individual training takes place: at the STAR® site in Göppingen, at your premises, or online.

FL3X Training FL3X Config

The FL3X Config software provides solutions for even the most complex of technical networking challenges. No matter what task you’re dealing with – whether it’s to do with restbus simulation, rapid prototyping, gateway nodes or signal manipulation – FL3X Config has the right solution. FL3X Config is intuitive and can be adapted to your own use case.

Matching Products

Matching Products

FL3X Interface-S

The FL3X Interface-S is the entry solution of the FL3X Interface Family with a 1000BASE-T Uplink Port to the Logger or Measurement PC. It can be used with the Standard CMP or PLP Logger Protocol for the usage with a datalogger or alternatively as a full functional Interface.

Details

FL3X Interface-L²

The FL3X Interface-L² is the high-end solution of the FL3X Interface Family with a 1000BASE-T Uplink Port to the Logger or Measurement PC. It can be used with the Standard CMP or PLP Logger Protocol for the usage with a datalogger or alternatively as a full functional Interface.

Details
Back to top